Category: Critical Care
Keywords: Hyperoxia, Mechanical Ventilation (PubMed Search)
Posted: 4/11/2017 by Rory Spiegel, MD
(Updated: 12/26/2024)
Click here to contact Rory Spiegel, MD
The deleterious effects of hyperoxia are becoming more and more apparent. But obtaining a blood gas to ensure normoxia in a busy Emergency Department can be burdensome. And while the utilization of a non-invasive pulse oximeter seems ideal, the threshold that best limits the rate of hyperoxia is unclear.
Durlinger et al in a prospective observational study demonstrated that an oxygen saturation 95% or less effectively limited the number of patients with hyperoxia (PaO2 of greater than 100 mm Hg). Conversely when an SpO2 of 100% was maintained, 84% of the patients demonstrated a PaO2 of greater than 100 mm Hg.
Durlinger EM, Spoelstra-de man AM, Smit B, et al. Hyperoxia: At what level of SpO2 is a patient safe? A study in mechanically ventilated ICU patients. J Crit Care. 2017;